Strata Carbon Assurance

Strata Environmental LIMS

The Industrial Laboratory Operating System • Eliminating Legacy LabWare
ISO/IEC 17025 Accredited
● Conrad AI Technical Director: Online Plant Command Center →
LABORATORY INFORMATICS ENCLAVE • LIMS.STRATACARBONASSURANCE.COM

Industrial Environmental Laboratory • Automated Accessioning Hub

Direct Agilent/Emerson Gas Chromatograph Ingestion • Two-Stage eCoC Barcode Intake • Zero Manual Excel Re-Keying

LabWare Displacement Rate: 100%
TURNAROUND CYCLE TIME
< 15 Minutes
✓ Down from 3 to 7 Days in Legacy LabWare
TRANSCRIPTION ERROR RATE
0.00%
✓ Eliminates 3.7% Manual PDF Re-keying Errors
ACTIVE LABORATORY QUEUE
24 Samples
● 18 Track A Online • 6 Track B Physical
WORM DIGITAL COAs ISSUED
1,420 CoAs
✓ Sealed in 15-Year S3/GCS Compliance WORM
SPECIFICATION SALUS-ACC-SPEC-2026-V2 • TWO-STAGE ACCESSIONING

Eliminating Phantom Bench Worklists with Architectural Track Separation

To prevent continuous industrial sensor streams from flooding laboratory worklists with phantom accessions or orphaned barcodes, Strata LIMS strictly separates Track A (Online Process Analyzers) from Track B (Physical Field & Plant Containers). Bench testing worklists begin only upon physical container arrival and thermal cooler inspection.

RECEIVING WINDOW BENCH SCANNER

Stage 2: Physical Barcode Scan-In & Cooler Thermal Inspection

Preservation Requirement: ≤ 6.0 °C
LIVE ACCESSION QUEUE • CUSTODY TRACEABILITY

Industrial Compliance Specimen Ledger (EPA Subpart RR / Class VI / RNG)

Accession ID Track Facility • Sampling Location Sample Matrix • Container Receipt Temp Analytical Test Method Assay Status Action
INSTRUMENT INTEGRATION • AGILENT 8890 GC

Raw Gas Chromatography Peak Table & ISO 17025 Mole Balance Gate

Mole Balance Total: 100.00% • ISO 17025 PASS

Replaces custom LabWare LIMS Basic parsing scripts with automatic peak-integration capture. Every carbon custody GC assay is normalized to a dry mole fraction per ASTM D1945/D6866 and validated against method blank and matrix spike QA/QC acceptance gates.

Agilent 8890 TCD/FID Chromatogram • ASTM D1945 Hydrocarbons & Permanent Gases Peak #4 (CO2): Retention Time 3.42 min • 99.42% Area
N2 (0.24%) CH4 (0.18%) CO2 (99.42% mol) H2S (18 ppm)
Peak # Analyte / Compound CAS Number Retention Time (min) Raw Peak Area Normalized Mol % Dry Basis Mol % QA/QC Standard
1 Nitrogen (N2) 7727-37-9 1.18 4,120 0.242% 0.243% PASS
2 Oxygen / Argon (O2/Ar) 7782-44-7 1.45 1,050 0.061% 0.061% PASS
3 Methane (CH4) 74-82-8 2.14 3,080 0.181% 0.182% PASS
4 Carbon Dioxide (CO2) 124-38-9 3.42 1,692,400 99.418% 99.502% SPEC COMPLIANT
5 Hydrogen Sulfide (H2S) 7783-06-4 4.82 312 0.0018% (18 ppm) 0.0018% < 20 ppm PIPELINE
6 Moisture (H2O Dewpoint) 7732-18-5 Chilled Mirror Dewpoint -48 °C 0.084% N/A (Dry Basis) < 30 lb/MMSCF
CONRAD WORKBENCH • ISO/IEC 17025 SIGN-OFF

Technical Director Review & Tamper-Proof Digital Certificate of Analysis (CoA)

Under ISO/IEC 17025, analytical results must be independently reviewed and certified by a qualified Technical Director before release. Conrad reviews calibration curves, duplicate relative percent difference (RPD < 2.0%), and blanks before digitally signing the Certificate of Analysis (CoA) into 15-year immutable WORM storage.

Official Certificate of Analysis
COA-STRATA-2026-Q3-0814
PENDING SIGN-OFF
TNI / NELAP Certified #TX-0982
Facility: Gulf Coast Cement Unit 01
Sample Point: Custody Transfer Skid (Tag: CEMS_CO2_OUTLET)
Collection Time: 2026-08-14 06:00:00 UTC
Analytical Protocol: ASTM D1945 / GPA 2261 Gas Chromatography
Certified Net Dry CO2 Purity: 99.502% mol
Moisture Content: 18.4 lbs/MMSCF (Dewpoint -48 °C)
Technical Director: Dr. Conrad Vance, PhD, Lead Chemist
Signature: Awaiting Director Review & Ed25519 Execution...
MACHINE-TO-MACHINE INTEROPERABILITY

Automated Strata Handshake Payload • Event: strata.ground_truth.v1

When the Technical Director signs the Certificate of Analysis, Strata LIMS emits an RFC 8785 canonical JSON payload over mutual TLS directly to Strata Carbon Assurance. This auto-closes the LIMS_GC_PURITY watermark and updates creditable net tonnage without human Excel transcription.

{ "event_type": "strata.ground_truth.v1", "document_id": "SALUS-ACC-SPEC-2026-V2", "accession_id": "SALUS-SHM-2026-0814-01", "facility_id": "FAC-MIDLOTHIAN-01", "coa_number": "COA-STRATA-2026-Q3-0814", "sampling_timestamp_utc": "2026-08-14T06:00:00Z", "approved_timestamp_utc": "2026-08-14T06:14:22Z", "turnaround_minutes": 14.37, "analyte_results": { "CO2_DRY_MOL_PCT": 99.502, "H2O_LBS_MMSCF": 18.4, "H2S_PPMV": 18.0, "CH4_MOL_PCT": 0.182 }, "watermark_action": "CLOSE_WATERMARK_LIMS_GC_PURITY", "net_tonnage_deration_factor": 0.99502, "iso17025_accreditation": "TNI-NELAP-TX-0982", "technical_director_sig": "sig:ed25519:conrad-director-signoff-7890-tx", "rfc8785_sha256": "3a4f89b1c20e7d58a12c84910efb32091248ca9810f274a18038fe09cb102874", "worm_receipt_uri": "s3://strata-worm-enclave/coas/2026-Q3/COA-STRATA-2026-Q3-0814.json" }
STRATEGIC DISPLACEMENT • SALUS-BRIEF-2026-V1

Head-to-Head Comparison: Legacy LabWare LIMS vs. Strata Automated LIMS

Legacy LIMS platforms like LabWare trap chemical assays in static PDF dead-ends, requiring manual spreadsheet re-keying that introduces a 3.7% error rate and triggers auditor CARs. Strata LIMS replaces legacy contracts with zero-touch machine lineage.

Operational Dimension Legacy LabWare LIMS + Manual PDFs Strata Automated Environmental LIMS
Sample Intake & Registration Technicians manually log samples at the bench, assign test templates by hand, and print physical barcode labels. Zero-Touch Event Trigger: AVEVA PI custody cycles, ERP weighbridge tickets, and well schedules auto-mint sample UUIDs with GPS lineage.
Vocabulary & Unit Standards Site-specific analyte codes (CO2_DRY vs CO2_MOL) require fragile custom LIMS Basic scripts to reconcile. Canonical EPA/ASTM Ontology: Automatically maps analytes to EPA SRS, CAS, and ASTM codes and normalizes units at intake.
Instrument Capture & QA/QC Batch file drops parsed by legacy serial/local scripts; calibration gas expirations tracked manually on clipboards. Direct Ingestion: Connects to Agilent/Emerson GCs with automated ISO 17025 blank/spike, duplicate RPD, and mole-balance gates.
Turnaround Cycle Time 3 to 7 business days per batch (manual bench entry & PDF generation). < 15 Minutes (event-driven intake to Conrad technical director electronic sign-off).
Manual Transcription Error Rate ~3.7% error rate across multi-sheet CoA re-keying into Excel models. 0.00% Error Rate: End-to-end cryptographic machine-to-machine payload delivery.
Downstream Audit Handoff Compliance analyst re-keys PDF numbers into Excel to adjust flowmeters; triggers VVB audit findings and CARs. Cryptographic Handshake: Emits RFC 8785 + Ed25519 signed JSON directly to Strata, auto-closing watermarks.
Commercial & Implementation Cost $150K to $400K+ legacy customization fees plus high annual maintenance. Turnkey Cutover: 14-day launch; eliminates legacy LIMS licensing across all enterprise plants.