Ops

Plant health and carbon auditing, on one console.

This is the ops page for the two products. Plant health is the read-only check set. Carbon auditing is the draft workpaper path those checks feed. No plant is connected to this page. A missing sample stays unevaluated. The drawings show the shape of a check. They are not meter readings. This page does not poll a historian, does not name a facility, and does not publish a health score.

Open Demo Portal →Book an evidence review ↗Contact us →
IN SHORT

Plant health and carbon auditing on one console: the checks, their gates, and the draft workpaper path the checks feed. This public page shows the console without a connected plant.

01 / CHECKS15

Plant-health checks in the local engine, including flat readings, mass balance, shell temperature, compressors, exchangers, calibration dates, and archive backfill.

02 / BESIDE THE RULES7

Model checks sit beside the rules. They do not replace a rule. No detection rate is published. The peer-group check stays unevaluated because no peer group is configured.

03 / INTERVAL15 min

Evidence is prepared on 15-minute intervals. A latest sample older than 15 minutes stays unevaluated.

04 / READ PATHRead only

The built connector is the AVEVA PI Web API, read only, plus a CSV history import. It does not change a setpoint. This page does not call it.

05 / A GAPUnevaluated

A missing input stays unevaluated. It is not stored as zero, and it is not treated as a healthy plant.

Plant health

The topics the console actually checks.

Each topic below is a check in the local engine. On this page every one of them is unevaluated, because no sample is connected. A draft note can cite a check. It does not close an alert, and no work-order endpoint is configured.

AEGIS-AUD-001 / 030

Mass flow and flat readings

The last 15, and the last 30, clean one-minute samples of stack flow or wellhead flow. A flat window while the upstream load still moves is critical, and it blocks. A window that is not uniform stays unevaluated.

AEGIS-AUD-002

Zero and span drift

Above 2.5 percent is critical and blocks. Above 1.5 percent with a seven-day slope is advisory. A missing drift input stays unevaluated.

AEGIS-AUD-003

Capture, injection, and line pack

Rates are metric tons per hour. Line pack is mass for the step, in metric tons. A gap above 3 percent of capture for more than 15 minutes is critical and blocks. A gap above 1.5 percent for more than 30 minutes warns. Missing line pack is not treated as zero. Capture at or below zero stays unevaluated.

AEGIS-MNT-001

Kiln shell bands

Zone 1 and zone 2. Above 780 F is critical, above 700 F is a warning, and above 620 F is advisory. None of the shell results block. A five-day rise above 8 F per day is advisory when the temperature itself is still healthy.

AEGIS-MNT-002 / 005

Compressors and vibration

AEGIS-MNT-002 warns above 0.25 inches per second, or when bearing temperature is more than 15 F above the supplied baseline. AEGIS-MNT-005 warns at the caller-supplied zone C and is critical at zone D. Both limits have to be supplied. The rule does not block.

AEGIS-MNT-003

Exchanger resistance

Differential pressure against production-well flow. Resistance above 1.25 times the clean baseline warns. Zero flow stays unevaluated.

AEGIS-MNT-004

Injectivity

Injection flow and wellhead pressure, against seven days earlier. A drop above 0.20 warns. Drive at or below zero stays unevaluated.

AEGIS-CAL-001 / 002

Calibration gate

Within 30 days of the due date is advisory. Within 7 days is a warning. After the due date, AEGIS-CAL-002 is critical and blocks. No due date stays unevaluated. The past-due block is the second check, not the 30-day check.

AEGIS-AUD-004 / HYG-004

Substitution and archive backfill

A substituted tier-1 value is critical and blocks. Archive backfill on a tier-1 tag is a separate check. It warns, and it blocks until reviewed. Flat, substituted, archive backfill, and missing stay different.

AEGIS-BAL-001

Kiln mass balance

Meal, fuels, measured CO2, and the capture outlet. A ratio above 0.06 warns and does not block. Missing factors stay unevaluated. They are not stored as zero.

AEGIS-BAL-002

Parasitic energy

Parasitic energy against wellhead mass flow. A ratio above 0.15 of the supplied baseline warns. The engine does not read a weather service.

BESIDE THE RULES

Seven model checks

Model checks sit beside the rules and do not replace them. No detection rate is published. The peer-group check stays unevaluated because no peer group is configured. A production model is not connected on this page.

Mass flow and drift

A flat reading beside a series that still moves.

The flatline checks read stack flow or wellhead flow. The balance check reads capture, injection, and line-pack mass. Missing line pack stays unevaluated.

DRAWING

What the flatline check is looking at

Solid line: a series that still moves. Drawing only.

Dashed line: a flat stretch. Drawing only.

A flat window while the related load still moves is the flatline result. The balance check compares capture, injection, and line pack over a trailing hour. A gap above 3 percent of capture for more than 15 minutes is critical and blocks. A gap above 1.5 percent for more than 30 minutes warns. Missing line pack is not treated as zero.

AEGIS-AUD-001

15 one-minute samples

Critical, and it blocks, when the flow window is flat and the upstream load still moves. A window that is not uniform stays unevaluated.

AEGIS-AUD-030

30 one-minute samples

The same flatline test on a longer window. Critical, and it blocks. It is not a second copy of the 15-sample check.

AEGIS-AUD-003

Capture, injection, line pack

Rates are metric tons per hour. Line pack is mass for the step, in metric tons. Capture at or below zero stays unevaluated.

AEGIS-AUD-004

Substituted tier-1 tag

A substituted tier-1 value is critical and blocks. Archive backfill on a tier-1 tag is a separate check, AEGIS-HYG-004, and it blocks until reviewed.

Shell, exchangers, and compressors

The bands are in the engine. The curves are drawings.

Kiln shell bands are 620 F, 700 F, and 780 F. Compressor zone limits are supplied by the caller. The engine does not hardcode them.

AEGIS-MNT-001 / KILN SHELL

Advisory, warning, and critical bands

780 F 700 F 620 F

Solid band: 620 F advisory.

Long dashes: 700 F warning.

Short dashes: 780 F critical.

Curve: a drawing under the advisory band, not a kiln.

None of the shell results block. A five-day rise above 8 F per day is advisory when the temperature itself is still healthy. Without a feed reference, that rise is degrees per day. Exchanger resistance above 1.25 times the clean baseline warns. Zero flow on that check stays unevaluated. An injectivity drop above 0.20 warns. Drive at or below zero stays unevaluated.

AEGIS-MNT-002 / AEGIS-MNT-005

Vibration against a supplied limit

Dashed line: 0.25 in/sec, the built warning in AEGIS-MNT-002.

Solid curve: a drawing, not a compressor.

AEGIS-MNT-002 warns above 0.25 inches per second, or when bearing temperature is more than 15 F above the supplied baseline. A singular covariance stays unevaluated. AEGIS-MNT-005 warns at the caller-supplied zone C and is critical at zone D. Both limits have to be supplied. The rule does not block. A draft note cites the check. It does not close an alert, and no work-order endpoint is configured.

The fifteen checks

Each row stays unevaluated on this page.

A sample marked not good, or marked questionable, keeps a credit record from being issued. That gate is not one of the fifteen checks. The thresholds are example settings, not guarantees. Industry packs cover all sixteen industries in the catalog.

Built plant-health checks, shown with example settings, not guarantees. Status on this public page is unevaluated because no sample is connected.
CheckWhat it readsGateThis page
AEGIS-AUD-001Last 15 clean one-minute samples of stack flow or wellhead flow, and the upstream load.Flat window while the load still moves: critical, and it blocks.Unevaluated
AEGIS-AUD-030The same flatline test on 30 clean one-minute samples.Critical, and it blocks.Unevaluated
AEGIS-AUD-002Zero drift and span drift.Above 2.5 percent: critical and blocks. Above 1.5 percent with a seven-day slope: advisory.Unevaluated
AEGIS-AUD-003Capture, injection, and line-pack mass.Above 3 percent of capture for more than 15 minutes: critical and blocks. Missing line pack stays unevaluated.Unevaluated
AEGIS-AUD-004Substitution flag on a tier-1 tag.Critical, and it blocks.Unevaluated
AEGIS-HYG-004Archive backfill on a tier-1 tag.Warning, and it blocks until reviewed.Unevaluated
AEGIS-BAL-001Kiln mass balance from meal, fuels, measured CO2, and capture outlet.Ratio above 0.06 warns and does not block. Missing factors stay unevaluated.Unevaluated
AEGIS-BAL-002Parasitic energy against wellhead mass flow.Above 0.15 of the baseline warns. The engine does not read a weather service.Unevaluated
AEGIS-MNT-001Kiln shell temperature, zone 1 and zone 2.Above 780 F critical, above 700 F warning, above 620 F advisory. None block.Unevaluated
AEGIS-MNT-002Bearing temperature, radial vibration, and discharge pressure.Warning above 0.25 in/sec, or bearing temperature more than 15 F over the supplied baseline.Unevaluated
AEGIS-MNT-003Exchanger differential pressure and production-well flow.Warning above 1.25 times the clean baseline. Zero flow stays unevaluated.Unevaluated
AEGIS-MNT-004Injection flow and wellhead pressure, against seven days earlier.Warning when injectivity drops more than 0.20.Unevaluated
AEGIS-MNT-005Compressor radial vibration against caller-supplied zone C and zone D.Warning at zone C. Critical at zone D. Limits are not hardcoded.Unevaluated
AEGIS-CAL-001Days until the calibration due date.Within 30 days: advisory. Within 7 days: warning. A past due date is the next check.Unevaluated
AEGIS-CAL-002The same due date after it has passed.Critical, and it blocks. No due date stays unevaluated.Unevaluated
Carbon auditing

What a plant-health result is allowed to feed.

Carbon auditing is the carbon assurance workpaper path. A blocking plant-health check keeps a credit record from being issued. A sample marked not good, or marked questionable, does too. That gate is not one of the fifteen checks. A draft is not a filed return, and it is not a tax determination.

01 / INTERVAL

The 15-minute record

Evidence is prepared on 15-minute intervals. A latest sample older than 15 minutes stays unevaluated. A blocking check keeps that interval from becoming an issued credit record. This page does not hold a live window, and it does not send an alert.

02 / 45Q

Section 45Q draft

The draft keeps the measurements, the interval checks, and the blanks in one line of sight for a 45Q conversation. It is not a filed return. An adviser decides whether 45Q applies.

03 / SUBPART RR

Subpart RR draft

The same draft path can carry a Subpart RR workpaper. It is not an EPA filing. The designated representative still files.

04 / SECTION 6418

Section 6418 draft

A section 6418 draft is not a transfer and not a tax determination. Section 6418 covers eligible federal tax credits, such as 45Q, transferred for cash. It does not cover voluntary carbon credits.

05 / BLANKS

A blank stays blank

The arithmetic is exact decimal. A missing coefficient is not stored as zero. A missing input stays unevaluated. The source stays with the result.

06 / RECORD

A tamper-evident record

Each interval and each review decision is kept in a tamper-evident evidence record. A taxpayer identification number stays out of it.

07 / MARKETPLACE

Two separate credit paths

Voluntary carbon credits can be sold directly or exchanged between plants. Eligible federal tax credits can only be transferred for cash under section 6418.

08 / REVIEW

Who still decides

Strata does not replace the independent reviewer, the designated representative, or the accountant. Qualified reviewers decide what applies, what is eligible, and what gets filed.

09 / PACKS

Sixteen industry packs

Every industry in the catalog has a pack built on the shared engine. Methodology applicability is confirmed facility by facility.

10 / LIMIT

What the draft is not

A draft does not close an alert, create a work order, or call a production model. It is not a verified credit, a registry approval, or a guaranteed financial outcome.

No plant is connected. Every plant-health row above is unevaluated. Carbon auditing topics name the draft path. They are not a customer filing or a measurement.

Plant health console ↗Carbon assurance ↗What credible means ↗Carbon Marketplace ↗
Start with your plant

Make your next reporting cycle less of a scramble.

Book an evidence review ↗Discuss a facility →