15 one-minute samples
Critical, and it blocks, when the flow window is flat and the upstream load still moves. A window that is not uniform stays unevaluated.
This is the plant health console. It lists the fifteen checks the local engine evaluates, the read path, and the gate for each check. No plant is connected to this page. A missing sample stays unevaluated. The drawings show the shape of a check. They are not meter readings.
Fifteen defined plant-health checks, plus seven labeled model checks, read your historian read only and flag equipment behavior and data-quality exceptions before they turn into reporting problems.
Plant-health checks in the local engine, including flat readings, mass balance, shell temperature, compressors, exchangers, calibration dates, and archive backfill.
Model checks sit beside the rules. They do not replace a rule. No detection rate is published. The peer-group check stays unevaluated because no peer group is configured.
Evidence is prepared on 15-minute intervals. A latest sample older than 15 minutes stays unevaluated.
The built connector is the AVEVA PI Web API, read only, plus a CSV history import. It does not change a setpoint. This page does not call it.
A missing input stays unevaluated. It is not stored as zero, and it is not treated as a healthy plant.
The flatline checks read stack flow or wellhead flow. The balance check reads capture, injection, and line-pack mass. Missing line pack stays unevaluated.
Solid line: a series that still moves. Drawing only.
Dashed line: a flat stretch. Drawing only.
A flat window while the related load still moves is the flatline result. The balance check compares capture, injection, and line pack over a trailing hour. A gap above 3 percent of capture for more than 15 minutes is critical and blocks. A gap above 1.5 percent for more than 30 minutes warns. Missing line pack is not treated as zero.
Critical, and it blocks, when the flow window is flat and the upstream load still moves. A window that is not uniform stays unevaluated.
The same flatline test on a longer window. Critical, and it blocks. It is not a second copy of the 15-sample check.
Rates are metric tons per hour. Line pack is mass for the step, in metric tons. Capture at or below zero stays unevaluated.
A substituted tier-1 value is critical and blocks. Archive backfill on a tier-1 tag is a separate check, AEGIS-HYG-004, and it blocks until reviewed.
Kiln shell bands are 620 F, 700 F, and 780 F. Compressor zone limits are supplied by the caller. The engine does not hardcode them.
Solid band: 620 F advisory.
Long dashes: 700 F warning.
Short dashes: 780 F critical.
Curve: a drawing under the advisory band, not a kiln.
None of the shell results block. A five-day rise above 8 F per day is advisory when the temperature itself is still healthy. Without a feed reference, that rise is degrees per day. Exchanger resistance above 1.25 times the clean baseline warns. Zero flow on that check stays unevaluated. An injectivity drop above 0.20 warns. Drive at or below zero stays unevaluated.
Dashed line: 0.25 in/sec, the built warning in AEGIS-MNT-002.
Solid curve: a drawing, not a compressor.
AEGIS-MNT-002 warns above 0.25 inches per second, or when bearing temperature is more than 15 F above the supplied baseline. A singular covariance stays unevaluated. AEGIS-MNT-005 warns at the caller-supplied zone C and is critical at zone D. Both limits have to be supplied. The rule does not block. A draft note cites the check. It does not close an alert, and no work-order endpoint is configured.
These topics are in the fifteen checks. Each one stays unevaluated on this page. The ops console carries the same topics next to carbon auditing.
Above 2.5 percent is critical and blocks. Above 1.5 percent with a seven-day slope is advisory. A missing drift input stays unevaluated.
Within 30 days of the due date is advisory. Within 7 days is a warning. After the due date, AEGIS-CAL-002 is critical and blocks. No due date stays unevaluated.
A substituted tier-1 value is critical and blocks. Archive backfill warns, and it blocks until reviewed. Flat, substituted, archive backfill, and missing stay different.
Meal, fuels, measured CO2, and the capture outlet. A ratio above 0.06 warns and does not block. Missing factors stay unevaluated.
A ratio above 0.15 of the supplied baseline warns. The engine does not read a weather service.
A drop above 0.20 against seven days earlier warns. Drive at or below zero stays unevaluated. Exchanger resistance above 1.25 times the clean baseline warns. Zero flow stays unevaluated.
A sample marked not good, or marked questionable, keeps a credit record from being issued. That gate is not one of the fifteen checks. The thresholds below are example settings, not guarantees.
| Check | What it reads | Gate | This page |
|---|---|---|---|
| AEGIS-AUD-001 | Last 15 clean one-minute samples of stack flow or wellhead flow, and the upstream load. | Flat window while the load still moves: critical, and it blocks. | Unevaluated |
| AEGIS-AUD-030 | The same flatline test on 30 clean one-minute samples. | Critical, and it blocks. | Unevaluated |
| AEGIS-AUD-002 | Zero drift and span drift. | Above 2.5 percent: critical and blocks. Above 1.5 percent with a seven-day slope: advisory. | Unevaluated |
| AEGIS-AUD-003 | Capture, injection, and line-pack mass. | Above 3 percent of capture for more than 15 minutes: critical and blocks. Missing line pack stays unevaluated. | Unevaluated |
| AEGIS-AUD-004 | Substitution flag on a tier-1 tag. | Critical, and it blocks. | Unevaluated |
| AEGIS-HYG-004 | Archive backfill on a tier-1 tag. | Warning, and it blocks until reviewed. | Unevaluated |
| AEGIS-BAL-001 | Kiln mass balance from meal, fuels, measured CO2, and capture outlet. | Ratio above 0.06 warns and does not block. Missing factors stay unevaluated. | Unevaluated |
| AEGIS-BAL-002 | Parasitic energy against wellhead mass flow. | Above 0.15 of the baseline warns. The engine does not read a weather service. | Unevaluated |
| AEGIS-MNT-001 | Kiln shell temperature, zone 1 and zone 2. | Above 780 F critical, above 700 F warning, above 620 F advisory. None block. | Unevaluated |
| AEGIS-MNT-002 | Bearing temperature, radial vibration, and discharge pressure. | Warning above 0.25 in/sec, or bearing temperature more than 15 F over the supplied baseline. | Unevaluated |
| AEGIS-MNT-003 | Exchanger differential pressure and production-well flow. | Warning above 1.25 times the clean baseline. Zero flow stays unevaluated. | Unevaluated |
| AEGIS-MNT-004 | Injection flow and wellhead pressure, against seven days earlier. | Warning when injectivity drops more than 0.20. | Unevaluated |
| AEGIS-MNT-005 | Compressor radial vibration against caller-supplied zone C and zone D. | Warning at zone C. Critical at zone D. Limits are not hardcoded. | Unevaluated |
| AEGIS-CAL-001 | Days until the calibration due date. | Within 30 days: advisory. Within 7 days: warning. A past due date is the next check. | Unevaluated |
| AEGIS-CAL-002 | The same due date after it has passed. | Critical, and it blocks. No due date stays unevaluated. | Unevaluated |
Seven model checks run beside these rules and do not replace them. No detection rate is published. A draft note cites the check. It does not close an alert, create a work order, or call a production model. Industry packs cover all sixteen industries in the catalog, on the same engine. Public pages do not show a live plant.
Deploy standalone for plant reliability or pair alongside carbon auditing. Aegis Industrial monitors custody transmitters, kiln thermal bands, compressor vibration, and mass balance closure without control-loop write risk.
Aegis Industrial can sit beside core telemetry or stand on its own. The facility fee is agreed in the order and is not published here. The checks include transmitter drift alerts, a DMZ spool, and operational logs.
Compares custody meter (e.g. Coriolis FT-402B) with check meter (e.g. ultrasonic FT-402A). Page-Hinkley cumulative change detection catches silent calibration loss before month-end accounting close.
DMZ collector queries AVEVA PI Web API via read-only HTTPS GET (SVC_STRATA_RO). Emits signed RFC 8785 canonical frames via outbound TCP 443 with per-plant X.509 client certificate mTLS.