Plant health

Catch the signal before it becomes a surprise.

This is the plant health console. It lists the fifteen checks the local engine evaluates, the read path, and the gate for each check. No plant is connected to this page. A missing sample stays unevaluated. The drawings show the shape of a check. They are not meter readings.

Open Demo Portal →Book an evidence review ↗Contact us →
IN SHORT

Fifteen defined plant-health checks, plus seven labeled model checks, read your historian read only and flag equipment behavior and data-quality exceptions before they turn into reporting problems.

01 / CHECKS15

Plant-health checks in the local engine, including flat readings, mass balance, shell temperature, compressors, exchangers, calibration dates, and archive backfill.

02 / BESIDE THE RULES7

Model checks sit beside the rules. They do not replace a rule. No detection rate is published. The peer-group check stays unevaluated because no peer group is configured.

03 / INTERVAL15 min

Evidence is prepared on 15-minute intervals. A latest sample older than 15 minutes stays unevaluated.

04 / READ PATHRead only

The built connector is the AVEVA PI Web API, read only, plus a CSV history import. It does not change a setpoint. This page does not call it.

05 / A GAPUnevaluated

A missing input stays unevaluated. It is not stored as zero, and it is not treated as a healthy plant.

Mass flow and drift

A flat reading beside a series that still moves.

The flatline checks read stack flow or wellhead flow. The balance check reads capture, injection, and line-pack mass. Missing line pack stays unevaluated.

DRAWING

What the flatline check is looking at

Solid line: a series that still moves. Drawing only.

Dashed line: a flat stretch. Drawing only.

A flat window while the related load still moves is the flatline result. The balance check compares capture, injection, and line pack over a trailing hour. A gap above 3 percent of capture for more than 15 minutes is critical and blocks. A gap above 1.5 percent for more than 30 minutes warns. Missing line pack is not treated as zero.

AEGIS-AUD-001

15 one-minute samples

Critical, and it blocks, when the flow window is flat and the upstream load still moves. A window that is not uniform stays unevaluated.

AEGIS-AUD-030

30 one-minute samples

The same flatline test on a longer window. Critical, and it blocks. It is not a second copy of the 15-sample check.

AEGIS-AUD-003

Capture, injection, line pack

Rates are metric tons per hour. Line pack is mass for the step, in metric tons. Capture at or below zero stays unevaluated.

AEGIS-AUD-004

Substituted tier-1 tag

A substituted tier-1 value is critical and blocks. Archive backfill on a tier-1 tag is a separate check, AEGIS-HYG-004, and it blocks until reviewed.

Shell, exchangers, and compressors

The bands are in the engine. The curves are drawings.

Kiln shell bands are 620 F, 700 F, and 780 F. Compressor zone limits are supplied by the caller. The engine does not hardcode them.

AEGIS-MNT-001 / KILN SHELL

Advisory, warning, and critical bands

780 F 700 F 620 F

Solid band: 620 F advisory.

Long dashes: 700 F warning.

Short dashes: 780 F critical.

Curve: a drawing under the advisory band, not a kiln.

None of the shell results block. A five-day rise above 8 F per day is advisory when the temperature itself is still healthy. Without a feed reference, that rise is degrees per day. Exchanger resistance above 1.25 times the clean baseline warns. Zero flow on that check stays unevaluated. An injectivity drop above 0.20 warns. Drive at or below zero stays unevaluated.

AEGIS-MNT-002 / AEGIS-MNT-005

Vibration against a supplied limit

Dashed line: 0.25 in/sec, the built warning in AEGIS-MNT-002.

Solid curve: a drawing, not a compressor.

AEGIS-MNT-002 warns above 0.25 inches per second, or when bearing temperature is more than 15 F above the supplied baseline. A singular covariance stays unevaluated. AEGIS-MNT-005 warns at the caller-supplied zone C and is critical at zone D. Both limits have to be supplied. The rule does not block. A draft note cites the check. It does not close an alert, and no work-order endpoint is configured.

More plant-health topics

The checks that sit beside the drawings.

These topics are in the fifteen checks. Each one stays unevaluated on this page. The ops console carries the same topics next to carbon auditing.

AEGIS-AUD-002

Zero and span drift

Above 2.5 percent is critical and blocks. Above 1.5 percent with a seven-day slope is advisory. A missing drift input stays unevaluated.

AEGIS-CAL-001 / 002

Calibration gate

Within 30 days of the due date is advisory. Within 7 days is a warning. After the due date, AEGIS-CAL-002 is critical and blocks. No due date stays unevaluated.

AEGIS-AUD-004 / HYG-004

Substitution and archive backfill

A substituted tier-1 value is critical and blocks. Archive backfill warns, and it blocks until reviewed. Flat, substituted, archive backfill, and missing stay different.

AEGIS-BAL-001

Kiln mass balance

Meal, fuels, measured CO2, and the capture outlet. A ratio above 0.06 warns and does not block. Missing factors stay unevaluated.

AEGIS-BAL-002

Parasitic energy

A ratio above 0.15 of the supplied baseline warns. The engine does not read a weather service.

AEGIS-MNT-004

Injectivity

A drop above 0.20 against seven days earlier warns. Drive at or below zero stays unevaluated. Exchanger resistance above 1.25 times the clean baseline warns. Zero flow stays unevaluated.

Open these topics on the ops console ↗
Appendix: the fifteen checks

Each row stays unevaluated on this page.

A sample marked not good, or marked questionable, keeps a credit record from being issued. That gate is not one of the fifteen checks. The thresholds below are example settings, not guarantees.

Built plant-health checks, shown with example settings, not guarantees. Status on this public page is unevaluated because no sample is connected.
CheckWhat it readsGateThis page
AEGIS-AUD-001Last 15 clean one-minute samples of stack flow or wellhead flow, and the upstream load.Flat window while the load still moves: critical, and it blocks.Unevaluated
AEGIS-AUD-030The same flatline test on 30 clean one-minute samples.Critical, and it blocks.Unevaluated
AEGIS-AUD-002Zero drift and span drift.Above 2.5 percent: critical and blocks. Above 1.5 percent with a seven-day slope: advisory.Unevaluated
AEGIS-AUD-003Capture, injection, and line-pack mass.Above 3 percent of capture for more than 15 minutes: critical and blocks. Missing line pack stays unevaluated.Unevaluated
AEGIS-AUD-004Substitution flag on a tier-1 tag.Critical, and it blocks.Unevaluated
AEGIS-HYG-004Archive backfill on a tier-1 tag.Warning, and it blocks until reviewed.Unevaluated
AEGIS-BAL-001Kiln mass balance from meal, fuels, measured CO2, and capture outlet.Ratio above 0.06 warns and does not block. Missing factors stay unevaluated.Unevaluated
AEGIS-BAL-002Parasitic energy against wellhead mass flow.Above 0.15 of the baseline warns. The engine does not read a weather service.Unevaluated
AEGIS-MNT-001Kiln shell temperature, zone 1 and zone 2.Above 780 F critical, above 700 F warning, above 620 F advisory. None block.Unevaluated
AEGIS-MNT-002Bearing temperature, radial vibration, and discharge pressure.Warning above 0.25 in/sec, or bearing temperature more than 15 F over the supplied baseline.Unevaluated
AEGIS-MNT-003Exchanger differential pressure and production-well flow.Warning above 1.25 times the clean baseline. Zero flow stays unevaluated.Unevaluated
AEGIS-MNT-004Injection flow and wellhead pressure, against seven days earlier.Warning when injectivity drops more than 0.20.Unevaluated
AEGIS-MNT-005Compressor radial vibration against caller-supplied zone C and zone D.Warning at zone C. Critical at zone D. Limits are not hardcoded.Unevaluated
AEGIS-CAL-001Days until the calibration due date.Within 30 days: advisory. Within 7 days: warning. A past due date is the next check.Unevaluated
AEGIS-CAL-002The same due date after it has passed.Critical, and it blocks. No due date stays unevaluated.Unevaluated

Seven model checks run beside these rules and do not replace them. No detection rate is published. A draft note cites the check. It does not close an alert, create a work order, or call a production model. Industry packs cover all sixteen industries in the catalog, on the same engine. Public pages do not show a live plant.

How a result is calculated ↗Feature list ↗Ops, with no plant connected ↗
Commercial Packaging & Architecture

Aegis Industrial: silent drift and plant health.

Deploy standalone for plant reliability or pair alongside carbon auditing. Aegis Industrial monitors custody transmitters, kiln thermal bands, compressor vibration, and mass balance closure without control-loop write risk.

PACKAGING • AGREED IN THE ORDER

Fee agreed in the order

Aegis Industrial can sit beside core telemetry or stand on its own. The facility fee is agreed in the order and is not published here. The checks include transmitter drift alerts, a DMZ spool, and operational logs.

DRIFT • CUMULATIVE DETECTION

Dual-meter divergence check

Compares custody meter (e.g. Coriolis FT-402B) with check meter (e.g. ultrasonic FT-402A). Page-Hinkley cumulative change detection catches silent calibration loss before month-end accounting close.

SECURITY • PURDUE LEVEL 3.5

Zero inbound firewall ports

DMZ collector queries AVEVA PI Web API via read-only HTTPS GET (SVC_STRATA_RO). Emits signed RFC 8785 canonical frames via outbound TCP 443 with per-plant X.509 client certificate mTLS.

Start with your plant

Make your next reporting cycle less of a scramble.

Book an evidence review ↗Discuss a facility →